Steady-state voltage, current, and power flow analysis for brownfield plants.
Power flow at every bus, voltage drop on every feeder, kVAR demand on every PCC. Modelled in ETAP or DigSILENT, signed off by a Chartered Engineer, delivered with an SLD-as-Code handover to your digital twin.
Plant loads drift. Motors get added, transformers age, capacitor banks fail, harmonic filters degrade. The single-line diagram on the wall is rarely the single-line in the field. A current load flow study reconciles the two, identifies undersized cables, flags transformers approaching nameplate, and quantifies the kVAR shortfall driving your demand penalties. Every refinery, every steel plant, every pharma site we touch starts here. Without an accurate load flow baseline, every downstream PSS deliverable · short circuit, coordination, arc flash, stability · inherits the gap.
CEng MIE India-signed deliverables · LiDAR-powered where applicable · digital twin handover ready · routes to the Power System Studies practice lead within 24 hours.
LiDAR-assisted as-built SLD verification, transformer + cable + motor nameplate capture, protection settings extraction, harmonic measurement campaign (where required).
ETAP or DigSILENT model authored from verified data. Network topology validated against your DCS/SCADA. Load profiles applied per operating case (normal, summer peak, monsoon, startup, emergency).
Minimum 6 operating cases run. Voltage profile at every bus, current loading on every cable, kVAR demand at every PCC tabulated. Contingency cases (N-1) included by default.
Undersized assets flagged, voltage drop violations isolated, kVAR correction sizing computed, transformer headroom for next 5-year capex quantified. Findings tied to IEEE 399 / IEC 60909 / NEMA MG-1 acceptance criteria.
Report signed by a Chartered Engineer (CEng MIE India). ETAP/DigSILENT model handed over with annotated SLD, ready for digital twin ingest.
Reports reference the international and national standards your regulators, F500 audit teams, and corporate process safety leads cite. Every deliverable signed by a Chartered Engineer (CEng MIE India).
Three landmark engagements from our verified roster · quantified outcomes, no client names disclosed without written permission.
Modelled 412 buses, 89 transformers, 1,800 motors. Identified 14 undersized feeders, sized 14 MVAR capacitor bank. Demand penalty avoidance eight-figure/year.
ETAP model rebuilt from LiDAR + DCS export. Flagged 3 transformers at 92% nameplate. Pre-empted Q4 expansion-driven overload.
DigSILENT load flow with 8 operating cases. Identified 5.8% voltage violation at remote MCC during compressor startup. Recommended on-load tap-changer retrofit.
Tell us your plant, region, and scope · a named Chartered Engineer responds within 24 hours.