Three-phase, single-line-to-ground, and line-to-line fault current analysis.
Maximum and minimum fault currents at every bus. Breaker interrupting duty audited. Symmetrical and asymmetrical components separated. Delivered in IEC 60909 + IEEE C37 + ANSI format · whichever your switchgear nameplates demand.
Every new transformer, every plant expansion, every utility upgrade changes the short-circuit landscape. Breakers rated 31.5 kA at commissioning may face 38 kA after the new utility connection. Catastrophic switchgear failure follows. A current short-circuit study quantifies the new fault levels, audits breaker and fuse interrupting duties, and gives you a clear retrofit or live-with-it decision. It also feeds protection coordination and arc flash · without an accurate short-circuit baseline, both inherit the gap.
CEng MIE India-signed deliverables · LiDAR-powered where applicable · digital twin handover ready · routes to the Power System Studies practice lead within 24 hours.
Utility short-circuit MVA at incomer confirmed in writing. Transformer impedances verified against nameplate. Motor contribution mapped to running load profile.
ETAP or DigSILENT short-circuit module configured. IEC 60909 c-factor or IEEE C37 X/R applied per regional preference. Both methods can be delivered side-by-side where required.
Three-phase, line-to-ground, line-to-line, double-line-to-ground at every bus. Maximum (utility max + max motor contribution) and minimum (utility min, no motors) cases tabulated.
Every breaker, fuse, MCCB, and cable cross-checked against momentary, interrupting, and short-time withstand ratings. Underrated equipment isolated with retrofit recommendations.
Report signed by a Chartered Engineer. Includes recommended breaker uprate list, current-limiting fuse options, and bus-tie reconfiguration alternatives where applicable.
Reports reference the international and national standards your regulators, F500 audit teams, and corporate process safety leads cite. Every deliverable signed by a Chartered Engineer (CEng MIE India).
Three landmark engagements from our verified roster · quantified outcomes, no client names disclosed without written permission.
Utility upgrade pushed bus fault from 31.5 kA to 36.2 kA. Identified 8 underrated panels, sized current-limiting reactor. Avoided nine-figure switchgear replacement.
Delivered IEC 60909 + IEEE C37 reports side-by-side for KSA technical authority + US licensor. Both accepted without rework.
Added 2 × 25 MW captive generators raised bus fault by 22%. Sized series reactor, retained existing switchgear. Capex deferral · seven-figure.
Tell us your plant, region, and scope · a named Chartered Engineer responds within 24 hours.